Fire Resistant Container Warehouse for KTC-IBC Containers

Fire Resistant Container Warehouse for KTC-IBC Containers

  • Designed for storing water-hazardous GHS 1-4 materials that promote fire hazards, flammable GHS 1-3 liquids, toxic and highly toxic materials, and waste requiring maintenance.
  • All sidewalls and roofs are fully coated with multilayer insulating elements, fire resistant (90 minutes) according to EN13501.
  • Steel construction with refractory thermal insulation.
  • Self-closing double-leaf doors, fire-retaining doors (90-minute fire resistance), have common technical approval.
  • Equipped with a lock, a self-closing mechanism with panic protection, and a system for controlling the closing of the door wings, the container is conveniently and safely stored.
  • Storage floor and drainage bath made of 5 mm steel sheet, removable steel trusses fitted in the WZ2.2 welded class controlled by EN ISO3452-1.
  • Due to the appropriate additional equipment (doors, fans, lighting, heating, air conditioners, shelves, stands), the warehouse can be tailored to your needs, allowing you to efficiently operate 60 liter or 200 l drums and store containers of various sizes and shapes.
  • Approved fire resistance (fire resistance 90 min) MPA Braunschweig, Dibt approval, CE mark.
Type Product code Product code
With the door 1350x2000 mm (EF) 124.602.382 -
With the door 2900x2000 mm (DF) - 124.602.383
Modeli WCS-KTC1/F90 WCS-KTC2/F90
Outside dimensions LxWxH, mm 1730x1840x2665 3270x1770x2480
Inner dimensions LxWxH, mm 1360x1260x1900 2900x1300x1900
Spill bath capacity, L 1000 1000
The warehouse holds KTC containers, pcs. 1 2
 
Optional warehouse equipment
Name Product code
Forced ventilation 124.903.121
Longitudinal luminaire 2x18W, EX ATEX, zone 2, WSC FASS / KTC 90 min. 124.903.125
Electric heater 2 kW, EX ATEX, WSC 90 min.. 124.903.104
Electric heater 3000 W, WSC 90 min. 124.903.105
Potential equalizer, WSC 90 min. 124.903.120
Distribution box, outer, WSC 90 min. 124.903.119
External air removal control system, EX ATEX, WSC 90 min. 124.903.110
Alarm system: emergency lamp, alarm siren, WSC 90 min 124.903.111

 

Download brochure
Fire resistant Container Warehouse F90 BCS CLASSIC

Fire resistant Container Warehouse F90 BCS CLASSIC. Fire-resistant for 90 minutes, used for the storage of water-hazardous GHS 1-4 materials promoting fire hazard, flammable GHS 1-3 liquids, toxic and highly toxic materials and waste

Fire resistant container Storage F90 BCS COMFORT

Fire resistant container Storage F90 BCS COMFORT. Steel construction with fire resistant thermal insulation (90 min.). For storage of GHS 1-4 materials that promote fire hazard, flammable GHS 1-3 liquids, toxic and highly toxic materials and waste

Fire Resistant Container Warehouse F90 BCS PREMIUM

Fire Resistant Container Warehouse F90 BCS PREMIUM. Provides effective protection against fire inside or outside the container. Steel construction with fire resistant thermal insulation (90 min.).

Fire Resistant Container Warehouse F90 BCS SUPERIOR

Fire Resistant Container Warehouse F90 BCS SUPERIOR, storage depth 2100 mm and storage height 2520 mm. Steel construction with fire resistant thermal insulation (90 min.).

Fire Resistant Container Warehouse for Barrels F90 WCS FASS

Fire Resistant Container Warehouse for Barrels F90 WCS FASS. Steel construction with fire resistant thermal insulation (90 min.).

Fire resistant container two level warehouse F90 with two side door

Fire resistant container two level warehouse F90 with two side door. For the storage of hazardous substances in the GHS 1-4 category
 

Fire resistant container two level warehouse F90 with sliding door

Fire resistant container two level warehouse F90 with sliding door. All side walls, floor slab and roof fully covered with multilayer insulating elements, fire resistant (90 minutes), according to EN13501.
 

Fire resistant container two level warehouse F90 with two side door to KTC-IBC

Fire resistant container two level warehouse F90 with two side door to KTC-IBC containers. Designed for storing water-hazardous GHS 1-4 materials that promote fire hazards, flammable GHS 1-3 liquids, toxic and highly toxic materials, and wasterequiring care with container storage depths of 1350 mm and storage height of 1400 mm.